Pipe Repair Clamp Stainless Steel Multi-Function Tee Products Repair Leakage

Short Description:

1.  Name:  Multi-fuction Stainless steel tee repair clamp.

2. Can solve different connecting and repairing problems.

3. Multi-fuction Reducing Tee , Band Repair Clamp Tee,  Flexibe Reducing Tee.

4. Can be used as a fast branch connection for new and old pipes.


Product Detail

Product Tags

Detail Information

Material: Stainless Steel Shape: Tee
Materials: AISI 304 Function: Repair Leak Pipes
Technics: Stamping And Welding Type: RCD-T CRT-1
Component / Material M1 M2
Skin 304 / 304L 316 / 316L
Bridge Plate 304 / 304L 316 / 316L
Junction Plate 304 / 304L 316 / 316L
Lugs 304 / 304L 316 / 316L
Locking Plate 304 / 304L 316 / 316L
Bolt $ Nut 304 / 304L 316 / 316L

- Refer to AS 4181-2013,DIN86128-1/2, CB/T4176-2013

 

DSC00102
DSC00110

Product Description

Product features:

1,The main band type of repair clamp are cast iron pipe,steel,cement tube,PE,PVC,glass steel tube and so on many kinds of pipeline rupture,perforation,and all kinds of crack damage provides a quick and economic repair method can greatly reduce material and labor costs.

2 ,This product installation convenient,quick,need only one person,a wrench can easily finish pipe repair,no longer needs a large number of workers,can need not stopped completely,not replace pipe pressure of piping of fast repair,the circular arc of the degree requirements for pipe low.

3, The stainless steel material,have anticorrosive,high toughness,hardness and other characteristics.

4 ,Band type of repair clamp have Double sealing ring,aft into tapered,as long as it is within the scope of arms hoop size,where all can realize effective overlap,uniform seal.Sealing ring sruface for fine mesh,can adapt to rough,the irregular surface porous pipes,around the entire pipeling sealing circle form effective.

5, This product use the card buckle type connection mode,and the product scope biggest suitable diameter can be up to 30 mm,can greatly reduce inventory,the product specification can be from DN1500-repair width can be up to 2000mm,almost can meet the size of pipe.

For the stainless steel repair clamp

1), clamp body: stailess steel SS 304 .

2), bolts and nuts : stailess steel SS 304 .

3), rubber : NBR/EPDM .

3), rubber : NBR/EPDM .

4),  Locking washer palte, Lugs,Receiver bars, Armour: stainless steel 304

5).Work pressure:PN10-PN16

6). packing :   wooden cases

For the DI repair clamp

1), clamp parts castings : Ductile iron GGG500-7 with fusion bonded epoxy coating

2), bolts and nuts : Carbon steel , Grade 4.8 , zinc plated .

3), rubber : EDPM .

4), clamp body :  Stainless steel SS304 .

5).Work pressure:PN16

6). packing : wooden cases

USE
1)  Clamps are designed for use on air,water and gas pipelines.

2) The clamps are dedicated product suited only to SABS 62 steel pipes,metric and imperial PVC pipes.

Material of Construction

1) Shell-Stainless Steel 316
2) Bolts-Steel to BS970 Grade 070M20
3) Bolt coating-zinc plated
4) Rubber Seal-E.P.D.M. to SABS 974

 

Specification

DN Range Length of 300mm Length of 400mm Length of 500mm
 Max Tee  Drilling Pressure  Max Tee  Drilling Pressure  Max Tee  Drilling Pressure
80 88-110 DN65 PN10/PN16 DN65 PN10/PN16 DN65 PN10/PN16
80 100-120 DN65 PN10/PN16 DN80 PN10/PN16 DN80 PN10/PN16
100 108-128 DN65 PN10/PN16 DN80 PN10/PN16 DN80 PN10/PN16
100 114-134 DN65 PN10/PN16 DN80 PN10/PN16 DN80 PN10/PN16
100 120-140 DN65 PN10/PN16 DN80 PN10/PN16 DN80 PN10/PN16
100 130-150 DN65 PN10/PN16 DN80 PN10/PN16 DN100 PN10/PN16
125 133-155 DN65 PN10/PN16 DN100 PN10/PN16 DN100 PN10/PN16
125 135-155 DN65 PN10/PN16 DN125 PN10/PN16 DN125 PN10/PN16
125 140-160 DN65 PN10/PN16 DN125 PN10/PN16 DN125 PN10/PN16
150 158-180 DN65 PN10/PN16 DN125 PN10/PN16 DN125 PN10/PN16
150 165-185 DN65 PN10/PN16 DN125 PN10/PN16 DN125 PN10/PN16
150 168-189 DN65 PN10/PN16 DN125 PN10/PN16 DN125 PN10/PN16
150 170-190 DN65 PN10/PN16 DN150 PN10/PN16 DN150 PN10/PN16
150 176-196 DN65 PN10/PN16 DN150 PN10/PN16 DN150 PN10/PN16
150 180-200 DN65 PN10/PN16 DN150 PN10/PN16 DN150 PN10/PN16
150 190-210 DN65 PN10/PN16 DN150 PN10/PN16 DN150 PN10/PN16
150 195-217 DN65 PN10/PN16 DN150 PN10/PN16 DN150 PN10/PN16
150 205-225 DN65 PN10/PN16 DN150 PN10/PN16 DN150 PN10/PN16
200 210-230 DN65 PN10/PN16 DN150 PN10/PN16 DN150 PN10/PN16
200 216-238 DN65 PN10/PN16 DN150 PN10/PN16 DN150 PN10/PN16
200 225-246 DN65 PN10/PN16 DN150 PN10/PN16 DN150 PN10/PN16
200 230-250 DN65 PN10/PN16 DN150 PN10/PN16 DN150 PN10/PN16
225 240-260 DN65 PN10/PN16 DN150 PN10/PN16 DN200 PN10
225 250-270 DN65 PN10/PN16 DN150 PN10/PN16 DN200 PN10
250 260-280 DN65 PN10/PN16 DN150 PN10/PN16 DN200 PN10
250 269-289 DN65 PN10/PN16 DN150 PN10/PN16 DN200 PN10
250 273-293 DN65 PN10/PN16 DN150 PN10/PN16 DN200 PN10
250 283-302 DN65 PN10/PN16 DN150 PN10/PN16 DN200 PN10

How to choose

Confirm the pipe O.D and leak point of which you want to repair. Choose the a right clamp type(single or double band, the width or length etc). Choose the right size belong to the pipe O.D. You are going to repair. E.g When pipe O.D ≤300mm, the clamp you choose should be at 80mm wider away from the leak point. When pipe O.D≥300mm, the length shoud be at least 100mm wilder for covering the leak point.

 

Once urgert repair needed to be doned on lagrg pipes, assemble some small range clamps to one several band repair clamp.

1.Make sure of the exact pipe O.D, which needed to be repaired.

2.Choose two or three small range clamps, make sure the sum of their range is equal to the O.Dof the pipe which you want to repair. E.g when repraiing a DN500mm DI pipe, O.D510mm, choose three DN150 clamps which range is 159-170 to make them be right size for this DN500.

3.The small clamps you use to assemble to a big one is not necessary to be the same size, but it would be better to the same.

 

Installation Instruction

1.Get well-reading before installing . Check parts to ensure that no damage has occurred during transit and that no parks are missing. Check the dimeter of the pipe and clamp specificions (on label)to ensure you have the proper clamp for your application.

2.Clean and eliminate any irregularities on the pipe ends.

3.On each pipe end, make a mark at a distance equal to half the width of the coupling.

4.Without openging the coupling, slide the coupling over on pipe end.

5.Bring the other pipe end a facing popsition. Make sure the pipes are aligned concentrically and that both pipe ends are curreclty supported. See tolerances indicated on the label.

6.Place the coupling between the marks and make sure that the armor is under the bolts. Do not exceed the torque requirements indicated on the product label.

7.Tighten the bolts alternately and evenly to the required torque. If there are three bolts, start with the center bolt, and begin tightening. Do not rotate the coupling or the pipe during or end tightening.

20191114162339_20188

Application

Crude Oil pipline, Gas/Natural gas/Fuel pipeline, Supply/Draign water pipeline, Aviation/Automotive special pipeline, Lubricating Oil pipeline, Mud slag pipline, Suction pipeline, Flushing power pipeline, Cable protection pipeline, Sea/Fresh water pipeline, Turbine pipeline, Air conditioning pipeline, Fire pipeline, Ventilation pipeline, Compressed air pipeline, and etc.

1232587127431352322
1232586992085995521

  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us